| CASE STUDY: Severe Post RK Ectasia | |||||||
This case study illustrates how Biometric Scleral Lenses addressed a specific patient's vision problems following RK surgery.
|
|||||||
| Topography OD |
|||||||
![]() |
The large areas of corneal steepening inferiorly and flattening superiorly are dramatically seen in this topography of the right eye. The left eye is similar. |
||||||
| Retinal Spot Diagram OD | |||||||
![]() |
The highly linear retinal light scatter indicates a severe amount of astigmatism of more than 10 diopters. Total higher order aberrations (HO Total) is 1.911 microns, a very high number. | ||||||
| From 20/200 to 20/30 with Biometric Lens |
|||||||
![]() |
The finished lens can be seen on the eye in this scan. This lens improved the patient’s visual acuity to 20/30. From this point forward, the patient was able to drive an automobile. | ||||||
| Retinal Spot Diagram with Lens | |||||||
![]() |
Total higher order aberrations were reduced only modestly, but the severe astigmatism was reduced dramatically. Work is continuing on reducing the aberrations further using wavefront optics. | ||||||